Pure Series is a water cooled chiller equipped with a choice of two scroll or screw compressor, and Shell & tube or plate heat exchanger evaporator and shell & tube or plate heat exchanger condenser, With cooling capacities ranging up to 868 kW, these chillers can meet a wide variety of customer needs.

Cooling Capacity: 36.08 kW – 868 kW
Refrigerant: R-410A or R-407c
Compressor: Two compressors
Cooling Type: Water-cooled
Applications: Industrial cooling, process cooling,
HVAC systems

Cooling tower compatibility

High energy efficiency

Long-lasting build

Teknik Özellikler

Pure Chill Teknik Özellikleri

Pure Chill Series 

PERFORMANCE VALUES A (Tin: 12 / Tout: 7 / T ambient: 35) / REFRIGERANT: R-410A

MODEL

 

RF-W2ST27

RF-W2ST210

RF-W2ST212

RF-W2ST215

RF-W2ST220

RF-W2ST225

RF-W2ST230

RF-W2ST240

RF-W2ST250

COOLING CAPACITY

Kw

36,08

52,88

61,16

78

105,2

129

161

208,40

256,6

kcal/h

30.993

45.424

52.536

67.002

90.367

110.553

138.299

179.016

220.419

COMPRESSOR QUANTITY

QTY

2

2

2

2

2

2

2

2

2

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

10,56

15,5

17,8

22,32

30,54

36,42

46,3

58

72,72

CAPACITY STEP

N

2

2

2

2

6

6

6

6

6

ABSORBED POWER

kw

10,56

15,5

17,8

22,32

30,54

36,42

46,3

58

72,72

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

EER

EER

3,42

3,41

3,44

3,49

3,44

3,53

3,48

3,59

3,53

WATER FLOW

m3/h

6,20

9,08

10,51

13,40

18,1

22,1

27,7

35,8

44,1

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

WATER CONNECTION

Inch

0

0   

0   

0   

0   

0

0

0

0

PERFORMANCE VALUES B (Tin: 12 / Tout: 7 / T ambient: 35)/ REFRIGERANT: R-410A 

MODEL

 

RF-W2ST47

RF-W2ST410

RF-W2ST412

RF-W2ST415

RF-W2ST420

RF-W2ST425

RF-W2ST430

RF-W2ST440

RF-W2ST450

COOLING CAPACITY

Kw

72,16

105,76

122,32

156

210,4

258

322

416,8

513,2

kcal/h

61.985

90.848

105.073

134.004

180.734

221.622

276.598

358.031

440.839

COMPRESSOR QUANTITY

QTY

4

4

4

4

4

4

4

4

4

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

21,12

31

35,6

44,64

61,08

72,84

92,6

116

145,44

CAPACITY STEP

N

4

4

4

4

12

12

12

12

12

ABSORBED POWER

kw

21,12

31

35,6

44,64

61,08

72,84

92,6

116

145,44

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

EER

EER

3,42

3,41

3,44

3,49

3,44

3,54

3,48

3,59

3,53

WATER FLOW

m3/h

12,40

18,17

21,01

26,8

36,15

44,32

55,3

71,61

88,2

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

WATER CONNECTION

Inch

0

0   

0   

0   

0   

0

0

0

0

 

 

 

PERFORMANCE VALUES C (Tin: 12 / Tout: 7 / T ambient: 35)/ REFRIGERANT: R-407C

MODEL

 

RF-W2ST270

RF-W2ST280

RF-W2ST290

RF-W2ST2100

RF-W2ST2110

RF-W2ST2125

RF-W2ST2140

RF-W2ST2160

RF-W2ST2180

COOLING CAPACITY

Kw

301,40

342,80

397,40

464,00

526,00

569,00

654,00

726,00

868,00

kcal/h

258.903

294.465

341.367

398.576

451.834

488.771

561.786

623.634

745.612

COMPRESSOR QUANTITY

QTY

2

2

2

2

2

2

2

2

2

COMPRESSOR TYPE

TYPE

SCREW

SCROLL

SCREW

SCREW

SCREW

SCREW

SCREW

SCREW

SCREW

COMPRESSOR POWER

kw

93,6

105,6

121,2

140,6

161

172,2

196,6

221,4

248,6

CAPACITY STEP

N

8

8

8

8

8

8

8

8

8

ABSORBED POWER

kw

93,6

105,6

121,2

140,6

161

172,2

196,6

221,4

248,6

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

EER

EER

3,22

3,25

3,28

3,30

3,27

3,30

3,33

3,28

3,49

WATER FLOW

m3/h

51,78

58,89

68,27

79,7

90,4

97,8

112,36

124,73

149,1

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

WATER CONNECTION

Inch

2"

2 1/2"

2 1/2"

3"

4"

4"

5"

6"

6"

Dimensions:

MODEL

RF-W2ST27

RF-W2ST210

RF-W2ST212

RF-W2ST215

RF-W2ST220

RF-W2ST225

RF-W2ST230

RF-W2ST240

RF-W2ST250

L (LENGTH)

mm

1700

1700

1700

2200

2200

2200

3000

3000

3000

W (WIDTH)

mm

1300

1300

1300

1500

1500

1500

1500

1500

1500

H (HEIGHT)

mm

1400

1400

1400

1400

1400

1400

1400

1400

1400

WEIGHT

Kg

500

550

570

600

600

600

600

600

600

MODEL

RF-W2ST47

RF-W2ST410

RF-W2ST412

RF-W2ST415

RF-W2ST420

RF-W2ST425

RF-W2ST430

RF-W2ST440

RF-W2ST450

L (LENGTH)

mm

1700

1700

2200

3000

3000

3000

3500

3500

4500

W (WIDTH)

mm

1300

1300

1500

1500

1500

1500

2100

2100

2100

H (HEIGHT)

mm

1400

1400

1400

1400

1400

1400

2000

2000

2000

WEIGHT

Kg

500

550

600

600

600

600

720

800

1000

MODEL

RF-W2ST270

RF-W2ST280

RF-W2ST290

RF-W2ST2100

RF-W2ST2110

RF-W2ST2125

RF-W2ST2140

RF-W2ST2160

RF-W2ST2180

L (LENGTH)

mm

3500

3500

3500

4500

4500

4500

5000

5500

5500

W (WIDTH)

mm

2100

2100

2100

2100

2100

2100

2100

2100

2100

H (HEIGHT)

mm

2000

2000

2000

2000

2000

2000

2000

2000

2000

WEIGHT

Kg

2200

2430

2520

2840

2900

3000

3050

3200

3400

*AREF SOĞUTMA reserves the right to change models, capacities and dimensions without prior notice.

Technical Overview

About Water-Cooled Chiller

Water-cooled chiller systems transfer heat through a water circuit and usually operate together with a cooling tower. They are preferred in large commercial and industrial applications for high efficiency and long service life.

A water-cooled chiller is a cooling unit that transfers heat to water and is generally used in large commercial and industrial applications. By cooling water, water-cooled chillers are used in air conditioning systems, industrial processes, and various other applications. Water-cooled chillers stand out for their high energy efficiency, and thanks to these features they are ideal for meeting large-scale cooling requirements. Furthermore, with their reliability and long service life, they play an important role in meeting the continuous cooling needs of businesses.

A water-cooled chiller cools water using a refrigerant. The cooling process takes place through a cycle that cools the water in the evaporator and transfers the heat to water in the condenser. These cooling systems typically operate together with a cooling tower, which allows the water to be cooled by the outside ambient air.

With its high energy efficiency, the water-cooled chiller is suitable for large-scale cooling requirements, while providing lower operating costs and offering an economical solution; being less affected by outside air temperature, the water-cooled chiller therefore delivers high performance even in hot weather, and being long-lasting and durable, the water-cooled chiller provides a reliable cooling solution.

Having a higher initial investment cost, the water-cooled chiller therefore requires a larger budget at the outset, while requiring a water source, the water-cooled chiller therefore consumes somewhat more water; in addition, being more complex to maintain, the water-cooled chiller therefore requires water treatment systems, and being more difficult and time-consuming to install, the water-cooled chiller can take some time to set up.

In water-cooled chiller systems, the cooling towers must be cleaned regularly and the water treatment systems must be inspected, while the water levels and system pressures must also be checked regularly; furthermore, it is important to clean the condenser and evaporator of the water-cooled chiller, and the electrical connections and motors of the water-cooled chiller must be checked regularly.

While water-cooled chillers are used for air conditioning systems in large commercial buildings, they are also preferred in industrial process cooling applications; in addition, cooling is provided by water-cooled chillers in data centers and telecommunications facilities, and they are also widely used in hospitals and laboratories.