+90 (212) 613 07 25
Air-Cooled Chiller

Pro Chill

Professional cooling solution for intensive production lines.

Pro Chill
Product Details

Pro Chill product family

Pro Chill Series is equipped with a choice of six scroll compressor, axial fan and Shell&tube evaporator, the chillers are also supplied with a water pump, making them compatible with water-glycol mixtures, and a storage tank that ensures precise temperature control, even when process thermal loads fluctuate significantly. With cooling capacities ranging up to 1144.8 kW, these chillers can meet a wide variety of customer needs.

Cooling Capacity: 123.72 kW – 1144.8 kW
Refrigerant: R-410A
Compressor: Six compressors
Cooling Type: Air-cooled
Applications: Industrial cooling, process cooling,
HVAC systems

Modular service infrastructure

Wide capacity range

Industrial components

Teknik Özellikler

Pro Chill Teknik Özellikleri

Pro Chill 2 Series

PERFORMANCE VALUES A (Tin: 15/ Tout: 10 / T ambient: 25) / REFRIGERANT: R-410A 

MODEL

 

RF-2F2ST67

RF-4F2ST610

RF-4F2ST612

RF-6F2ST615

RF-8F2ST620

RF-8F2ST625

RF-10F2ST630

RF-14F2ST640

RF-16F2ST650

COOLING CAPACITY

Kw

138

202,86

229,5

296,28

398,76

487,74

612

787,8

967,8

kcal/h

118.542

174.257

197.141

254.505

342.535

418.969

525.708

676.720

831.340

COMPRESSOR QUANTITY

QTY

6

6

6

6

6

6

6

6

6

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

25,8

36

42

53,16

72,48

87

110,52

139,38

173,1

CAPACITY STEP

N

6

6

6

6

18

18

18

18

18

ABSORBED POWER

kw

33,48

48,5

54,5

65,16

92,98

107,5

136,02

167,38

205,1

EER

EER

4,12

4,18

4,21

4,55

4,3

4,5

4,5

4,7

4,7

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

2

4

4

6

8

8

10

14

16

FAN SIZE

mm

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

WATER FLOW

m3/h

23,71

34,85

39,43

50,90

68,5

83,8

105,1

135,3

166,3

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

PERFORMANCE VALUES B (Tin: 10/ Tout: 15/ T ambient: 35)/ REFRIGERANT: R-410A 

MODEL

 

RF-2F2ST67

RF-4F2ST610

RF-4F2ST612

RF-6F2ST615

RF-6F2ST620

RF-8F2ST625

RF-10F2ST630

RF-12F2ST640

RF-16F2ST650

COOLING CAPACITY

Kw

120

178,2

201,78

260

350

429

537

694,80

854,4

kcal/h

103.080

153.074

173.329

223.340

300.650

368.511

461.283

596.833

733.930

COMPRESSOR QUANTITY

QTY

6

6

6

6

6

6

6

6

6

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

31,56

46,44

52,56

66,84

91,62

109,44

139,14

175,2

218,64

CAPACITY STEP

N

6

6

6

6

18

18

18

18

18

ABSORBED POWER

kw

39

58,94

65

83,34

108,12

130,94

164,64

199,2

250,64

EER

EER

3,08

3,02

3,10

3,12

3,24

3,28

3,26

3,49

3,41

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

2

4

4

6

6

8

10

12

16

FAN SIZE

mm

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

WATER FLOW

m3/h

20,62

30,61

34,67

44,7

60,13

73,70

92,3

119,37

146,8

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

PERFORMANCE VALUES C (Tin: 10/ Tout: 15 / T ambient: 40) / REFRIGERANT: R-410A 

MODEL

 

RF-2F2ST67

RF-4F2ST610

RF-4F2ST612

RF-6F2ST615

RF-6F2ST620

RF-8F2ST625

RF-10F2ST630

RF-12F2ST640

RF-16F2ST650

COOLING CAPACITY

Kw

111,78

164,88

186,9

240,24

324,60

397,14

496,74

644,40

793,2

kcal/h

96.019

141.632

160.547

206.366

278.831

341.143

426.700

553.540

681.359

COMPRESSOR QUANTITY

QTY

6

6

6

6

6

6

6

6

6

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

34,8

51,9

58,44

74,52

102,24

122,1

155,04

194,34

243,6

CAPACITY STEP

N

6

6

6

6

18

18

18

18

18

ABSORBED POWER

kw

43,3

64,4

70,94

91,02

118,74

142,6

180,54

218,34

275,6

EER

EER

2,58

2,56

2,63

2,64

2,73

2,78

2,75

2,95

2,88

POWER SUPPLY

V/Ph/Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

2

4

4

6

6

8

10

12

16

FAN SIZE

mm

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

800Ø

WATER FLOW

m3/h

19,20

28,33

32,11

41,3

55,8

68,2

85,34

110,71

136,3

EVAPORATOR TYPE

ST / PH

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

shell & tube

Water pump

Yes / No

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

TANK CAPACITY

LT

270

270

270

350

350

500

500

/

/

WATER CONNECTION

Inch

2"

2 1/2"

2 1/2"

3"

4"

4"

5"

6"

6"

Dimensions:

MODEL

RF-2F2ST67

RF-4F2ST610

RF-4F2ST612

RF-6F2ST615

RF-6F2ST620

RF-8F2ST620

RF-8F2ST625

RF-10F2ST630

RF-12F2ST640

RF-14F2ST640

RF-16F2ST650

L (LENGTH)

mm

2750

2900

2900

4100

4100

5200

5200

6300

7500

8650

9820

W (WIDTH)

mm

1350

2250

2250

2250

2250

2250

2250

2250

2250

2250

2250

H (HEIGHT)

mm

2500

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

WEIGHT

Kg

1200

1800

2000

2500

3200

3200

3800

4300

4600

4850

4850

*AREF SOĞUTMA reserves the right to change models, capacities and dimensions without prior notice.

Technical Overview

About Air-Cooled Chiller

Air-cooled chiller systems transfer heat to the outside air through condenser fans. With practical installation, low maintenance needs and a structure suited to outdoor applications, they are widely used in commercial and industrial facilities.

An air-cooled chiller is a cooling unit that transfers heat to the ambient air and is commonly used in commercial and industrial applications. Air-cooled chillers cool water for use in air conditioning, industrial processes, and a variety of other applications.

An air-cooled chiller uses a refrigerant to cool water. The cooling process takes place through a cycle in which the water is cooled in the evaporator and the heat is transferred to the air in the condenser. Fans dissipate the heat into the ambient air, cooling the system.

It is easier to install and lower in cost. Since it consumes no water, it does not require a water source. It requires less maintenance because there are no issues related to water treatment or water piping. Because it can be used outdoors, it saves indoor floor space.

Its operating efficiency depends on the outdoor air temperature; performance may drop in hot weather. The noise level is high because the fans run continuously. The cooling capacity is generally lower than that of water-cooled chillers.

The fans and condensers need to be cleaned regularly. It is important to check and replace the filters frequently. The refrigerant levels and system pressures should be checked regularly. The electrical connections and motors need to be inspected regularly.

Air conditioning systems in commercial buildings Industrial process cooling Data centers Hospitals and laboratories Food and beverage industry Plastic injection molding facilities Extrusion facilities Metal and steel processing facilities

Cooling capacity and energy efficiency The environmental conditions of the installation site (air temperature, humidity, etc.) Ease of maintenance and service Noise level Initial investment cost and operating costs