+90 (212) 613 07 25
Air-Cooled Chiller

Smart Chill

Balanced performance for compact process cooling.

Smart Chill
Product Details

Smart Chill product family

Each model in Smart Chill Series is equipped with a choice of onecompressor, axial fan and brazed plate evaporatorthe chillers are also supplied with a water pump, making them compatible with water-glycol mixtures, and a storage tank that ensures precise temperature control, even when process thermal loads fluctuate significantly. With cooling capacities ranging up to 58.5 kW, these chillers can meet a wide variety of customer needs.

Cooling Capacity: 3,6 kW - 58.5 kW
Refrigerant: R-404A & R-407c and R-410A
Compressor: Single compressor
Cooling Type: Air-cooled
Applications: Industrial cooling, process cooling,
HVAC systems

Quick installation

Low maintenance requirements

Suitable for outdoor applications

Teknik Özellikler

Smart Chill Teknik Özellikleri

Smart Chill 2 Series

PERFORMANCE VALUES A (Tin: 15/ Tout: 10 / T ambient: 25)

GAS

407c / 404A

410A

MODEL

 

RF-1F1PH11

RF-1F1PH12

RF-1F1PH13

RF-1F1PH14

RF-1F1PH15

RF-1F1PH17

RF-2F1PH18

RF-2F1PH110

RF-2F1PH112

RF-2F1PH115

COOLING CAPACITY

Kw

4,20

7,60

10,41

11,87

17,57

23

33,38

33,81

38,25

49,38

kcal/h

3.608

6.528

8.942

10.196

15.093

19.757

28.673

29.043

32.857

42.417

COMPRESSOR QUANTITY

QTY

1

1

1

1

1

1

1

1

1

1

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

2,6

1,97

2,34

2,40

3,75

4,29

6

6,2

6,93

8,85

CAPACITY STEP

N

1

1

1

1

1

1

1

1

1

1

ABSORBED POWER

kw

3,95

3,32

4,04

4,1

5,85

6,39

8,7

8,9

9,63

11,55

EER

EER

1,06

2,29

2,58

2,90

3,00

3,60

3,84

3,80

3,97

4,28

POWER SUPPLY

V/Ph/Hz

220V-1ph-50Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

1

1

1

1

1

1

2

2

2

2

FAN SIZE

mm

350Ø

400Ø

400Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

WATER FLOW

m3/h

0,7

1,3

1,8

2,0

3,0

4,0

5,7

5,8

6,6

8,5

EVAPORATOR TYPE

ST / PH

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

PERFORMANCE VALUES B (Tin: 15/ Tout: 10  / T ambient: 35)

GAS

407c / 404A

410A

MODEL

 

RF-1F1PH11

RF-1F1PH12

RF-1F1PH13

RF-1F1PH14

RF-1F1PH15

RF-1F1PH17

RF-2F1PH18

RF-2F1PH110

RF-2F1PH112

RF-2F1PH115

COOLING CAPACITY

Kw

3,60

6,63

9,0

10,23

15

20

29,23

29,7

33,63

43,32

kcal/h

3.092

5.695

7.731

8.788

12.842

17.180

25.109

25.512

28.888

37.212

COMPRESSOR QUANTITY

QTY

1

1

1

1

1

1

1

1

1

1

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

3,10

2,21

3

2,97

4,32

5,26

7,54

7,73

8,75

11,14

CAPACITY STEP

n

1

1

1

1

1

1

1

1

1

1

ABSORBED POWER

kw

4,5

3,56

4,7

4,67

6,42

7,36

10,24

10,43

11,45

13,84

EER

EER

0,8

1,86

1,91

2,19

2,33

2,72

2,85

2,85

2,94

3,13

POWER SUPPLY

V/Ph/Hz

220V-1ph-50Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

1

1

1

1

1

1

2

2

2

2

FAN SIZE

mm

350Ø

400Ø

400Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

WATER FLOW

m3/h

0,6

1,1

1,5

1,8

2,6

3,4

5,0

5,1

5,8

7,4

EVAPORATOR TYPE

ST / PH

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

PERFORMANCE VALUES C (Tin: 15/ Tout: 10 / T ambient: 40)

GAS

407c / 404A

410A

MODEL

 

RF-1F1PH11

RF-1F1PH12

RF-1F1PH13

RF-1F1PH14

RF-1F1PH15

RF-1F1PH17

RF-2F1PH18

RF-2F1PH110

RF-2F1PH112

RF-2F1PH115

COOLING CAPACITY

Kw

3

5,51

8,32

9,50

13,63

18,62

27

27,5

31,15

40

kcal/h

2.577

4.733

7.147

8.161

11.708

15.995

23.193

23.623

26.758

34.360

COMPRESSOR QUANTITY

QTY

1

1

1

1

1

1

1

1

1

1

COMPRESSOR TYPE

TYPE

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

COMPRESSOR POWER

kw

3,70

2,5

3,2

3,32

4,6

5,8

8,43

8,65

9,73

12,42

CAPACITY STEP

n

1

1

1

1

1

1

1

1

1

1

ABSORBED POWER

kw

5,05

3,85

4,9

5,02

6,7

7,9

11,13

11,35

12,43

15,12

EER

EER

0,594

1,431

1,698

1,892

2,034

2,357

2,426

2,423

2,506

2,646

POWER SUPPLY

V/Ph/Hz

220V-1ph-50Hz

380- 400V-3ph-50Hz

PROTECTION CLASS

 IP 

IP54

FAN QUANTITY

QTY

1

1

1

1

1

1

2

2

2

2

FAN SIZE

mm

350Ø

400Ø

400Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

500Ø

WATER FLOW

m3/h

0,5

0,9

1,4

1,6

2,3

3,2

4,6

4,7

5,4

6,9

EVAPORATOR TYPE

ST / PH

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Plate exchanger

Water pump

Yes / No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

TANK CAPACITY

LT

12LT

45LT

45LT

60LT

60LT

60LT

60LT

180LT

180LT

180LT

WATER CONNECTION

Inch

1/2"

1/2"

3/4"

1"

1"

1"

1"

1 1/4"

1 1/4"

1 1/4"

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

L (LENGTH)

mm

820

1000

1000

1200

1200

1750

1750

1730

1730

1730

W (WIDTH)

mm

540

785

785

785

785

760

760

1010

1010

1010

H (HEIGHT)

mm

900

1000

1000

1150

1150

1150

1150

1600

1600

1600

WEIGHT

kg

60KG

130KG

130KG

160kg

160kg

220kg

250kg

350kg

350kg

380kg

*AREF SOĞUTMA reserves the right to change models, capacities and dimensions without prior notice.

Technical Overview

About Air-Cooled Chiller

Air-cooled chiller systems transfer heat to the outside air through condenser fans. With practical installation, low maintenance needs and a structure suited to outdoor applications, they are widely used in commercial and industrial facilities.

An air-cooled chiller is a cooling unit that transfers heat to the ambient air and is commonly used in commercial and industrial applications. Air-cooled chillers cool water for use in air conditioning, industrial processes, and a variety of other applications.

An air-cooled chiller uses a refrigerant to cool water. The cooling process takes place through a cycle in which the water is cooled in the evaporator and the heat is transferred to the air in the condenser. Fans dissipate the heat into the ambient air, cooling the system.

It is easier to install and lower in cost. Since it consumes no water, it does not require a water source. It requires less maintenance because there are no issues related to water treatment or water piping. Because it can be used outdoors, it saves indoor floor space.

Its operating efficiency depends on the outdoor air temperature; performance may drop in hot weather. The noise level is high because the fans run continuously. The cooling capacity is generally lower than that of water-cooled chillers.

The fans and condensers need to be cleaned regularly. It is important to check and replace the filters frequently. The refrigerant levels and system pressures should be checked regularly. The electrical connections and motors need to be inspected regularly.

Air conditioning systems in commercial buildings Industrial process cooling Data centers Hospitals and laboratories Food and beverage industry Plastic injection molding facilities Extrusion facilities Metal and steel processing facilities

Cooling capacity and energy efficiency The environmental conditions of the installation site (air temperature, humidity, etc.) Ease of maintenance and service Noise level Initial investment cost and operating costs